Free Delivery

Easy Returns

Minimum 1-Year Warranty

12V Air/Rain Caravan Roof Vent – 14 Inch Manual Lid

(8 customer reviews)

$225.00

Clock Icon Order now for dispatch on Tuesday 15th September!

92 in stock

SKU: TRA-RVM5000-AIR Categories: ,

The 12V caravan roof vent TRA-RVM5000-AIR from TRA Australia combines powerful reversible ventilation with an Air/Rain lid that allows the fan to operate with the lid closed at approximately 20% airflow. Designed for a standard 14 × 14 inch roof opening, it features multi-speed reversible airflow with 2 intake speeds and 3 extraction speeds, a removable insect screen and airflow up to 25.76 m³/min.

Why Choose the TRA 12V Air/Rain Caravan Roof Vent?

Air/Rain Lid – Ventilation While Closed
The Air/Rain lid allows the fan to continue operating with the lid closed at approximately 20% airflow, providing ongoing ventilation even during rain.
Multi-Speed Reversible Airflow
Choose from 3 extraction speeds (Low, Medium and High) or 2 intake speeds (Low and High), giving you flexible control over airflow in or out of your caravan or RV.
High Airflow Performance
Delivers up to 25.76 m³/min of airflow on high speed with the lid open, providing effective powered ventilation for caravan and RV interiors.
Standard 14 × 14 Inch Roof Opening
Designed for a common 14 × 14 inch caravan and RV roof opening, making it suitable for new installations and compatible replacement applications.
Removable Insect Screen
The insect screen helps keep insects outside and can be removed for easier cleaning and maintenance.
Built-In Overload Protection Fuse
An integrated fuse provides circuit protection for the roof vent’s electrical system.
Trim-to-Suit Internal Garnish
The 150 mm internal garnish can be trimmed to suit the required roof thickness and provide a neat interior finish.

Technical Specifications

SpecificationDetails
SKUTRA-RVM5000-AIR
Power Supply12V
Power18W
Current Draw1.6A on high speed
Roof Opening14 × 14 inch
Lid TypeManual Air/Rain lid
Closed-Lid OperationYes – approximately 20% airflow with lid closed
Airflow DirectionReversible – intake (IN) and extraction (OUT)
Extraction Speeds (OUT)3 – Low, Medium and High
Intake Speeds (IN)2 – Low and High
High-Speed Airflow25.76 m³/min
Medium-Speed Airflow18.28 m³/min
Low-Speed Airflow13.38 m³/min
Fan SpeedUp to 1200 RPM
Internal Garnish HeightApproximately 150 mm – trim to suit
Minimum Roof Thickness40 mm when installed with internal garnish
Insect ScreenRemovable for cleaning
Circuit ProtectionBuilt-in overload protection fuse
Warranty1-year product warranty

Ideal Applications

Caravans and camper trailers
Motorhomes and RVs
14 × 14 inch roof openings
Applications requiring ventilation during rain
New installations and compatible replacement applications

What’s Included

TRA-RVM5000-AIR roof vent assembly
Manual Air/Rain lid
Removable insect screen
Trim-to-suit internal garnish

Installation & Fitment

This 12V caravan roof vent is designed for a standard 14 × 14 inch roof opening. When replacing an existing roof vent, measure the actual roof opening, roof thickness and available mounting area before ordering rather than relying only on the nominal size of the existing vent.

The supplied internal garnish is approximately 150 mm high and can be trimmed to suit the particular roof thickness. The installation instructions also specify that the lid hinge should face towards the front of the vehicle.

Important replacement fitment note: A matching 14 × 14 inch roof opening does not by itself guarantee direct replacement compatibility. Before replacing an existing roof vent, compare the opening, available mounting area, roof thickness, electrical requirements and surrounding clearances.

Important flange sealing note: During installation, the external plastic roof flange should be fully sealed and covered with a suitable compatible sealant, including the exposed flange surface and mounting screw areas. Leaving the plastic flange exposed to weather and UV over time can cause the plastic to become brittle and may result in cracking or breakage. Only use sealants compatible with the plastic flange and vehicle roof surface.

Important installation note: TRA Australia recommends professional installation by an appropriately licensed installer. Warranty does not cover faults or damage resulting from incorrect installation, including water ingress, electrical damage or damage caused during installation.

💡 TRA Expert Tip

The Air/Rain lid makes this 12V caravan roof vent particularly useful when ongoing ventilation is important. With the lid closed, the TRA-RVM5000-AIR can continue operating at approximately 20% airflow, allowing ventilation during rain without leaving the roof vent fully open.

Installation Instructions & Operating Guide

View the installation instructions and operating guide for the TRA-RVM5000-AIR caravan roof vent, including installation, wiring, fitment and operating information.

View Installation Instructions & Operating Guide →

Compare 14-Inch Caravan Roof VentsCompare TRA’s manual, powered and rain-sensing 14-inch roof vents to find the right ventilation features for your caravan or RV.View 14-Inch Roof Vents →
Frequently Asked Questions about the 12V Air/Rain Caravan Roof Vent
Can the fan operate with the Air/Rain lid closed?
Yes. This 12V caravan roof vent can continue operating with the Air/Rain lid closed at approximately 20% airflow, including during rain.
What size roof opening does the TRA-RVM5000-AIR require?
This 12V caravan roof vent is designed for a standard 14 × 14 inch caravan or RV roof opening. Always measure the actual opening before ordering a replacement roof vent.
Does the TRA-RVM5000-AIR have reversible airflow?
Yes. It provides reversible airflow with 2 intake speeds and 3 extraction speeds, allowing air to be drawn into or exhausted from the vehicle.
How many fan speeds does it have?
The vent provides 3 extraction speeds – Low, Medium and High – and 2 intake speeds – Low and High.
How much airflow does this 12V caravan roof vent provide?
With the lid open, rated airflow is 13.38 m³/min on low, 18.28 m³/min on medium and up to 25.76 m³/min on high. With the Air/Rain lid closed, the fan operates at approximately 20% airflow.
Can the insect screen be removed for cleaning?
Yes. The insect screen is removable, making it easier to access for cleaning and maintenance.
Does the external plastic roof flange need to be sealed?
Yes. During installation, the external plastic roof flange should be fully sealed and covered with a suitable compatible sealant, including the exposed flange and mounting screw areas. Leaving the plastic exposed to weather and UV over time can cause it to become brittle and may lead to cracking or breakage.
Can it replace another 14 × 14 inch caravan roof vent?
It may suit compatible replacement applications using the same 14 × 14 inch roof opening. However, opening size alone does not guarantee direct compatibility, so the mounting area, roof thickness, electrical requirements and surrounding clearances should also be checked before ordering.
Should the TRA-RVM5000-AIR be professionally installed?
Yes. TRA Australia recommends professional installation by an appropriately licensed installer. Warranty does not cover faults or damage resulting from incorrect installation, including water ingress, electrical damage or damage caused during installation.
SHARE THIS PRODUCT

4.8
Based on 8 reviews
5
75
75%
4
25
25%
3
0%
2
0%
1
0%
1-3 of 8 reviews
  1. very good quality vent the best i have used

    • Thanks Roger! 🙌 We’re so glad to hear you’re impressed with the quality of the TRA Manual 12V Air/Rain Roof Vent Hatch. Hearing it’s the best you’ve used means a lot — enjoy the comfort and reliability it brings to your setup! 🚐🌤️

  2. Very happy with product.

    • Thanks Neil! We’re glad to hear you’re happy with your new roof vent hatch — enjoy the fresh air and peace of mind on the road. 🌬️🚐

  3. Seems perfect, just need to fit it!

    • Thanks, Craig! Sounds like you’re all set—hope the installation goes smoothly. Let us know how it works once it’s in place! 🚐🔧

Q & A

Ask a question
What is the height of the vent when closed? Thank you Josh asked on January 8, 2025

Hey Josh, how are you?
It sits roughly 11cm above roof line. I would allow for 12cm.
Thanks
Nathan
TRA

Team TRA answered on January 9, 2025 store manager
(0) (0)
Add an answer
How do I take the mesh screen off from the inside to clean it please. Vanessa Davis asked on September 29, 2024

Hey Vanessa,
There will be a lip around the screen, please pull on this and slowing work your way around the diameter of the screen. Some force will be needed as its fitted snug with 6-7 lugs.
Thank you

Team TRA answered on September 29, 2024 store manager
(0) (0)
Add an answer
Do you all sell this style of vented covers in the event one of them is broken or do you have to buy a new unit again? James asked on September 24, 2024

Hey James,
Yes we do have lids suitable for this model in stock. They are $49.95 plus delivery fee to your location.
If you are interested please email your full name and delivery address to [email protected]
Thank you

Team TRA answered on September 24, 2024 store manager
(0) (0)
Add an answer